No warranty of accuracy is given concerning the contents of the information contained in this publication. To the extent permitted by law no liability (including liability to any person by reason of negligence) will be accepted by SolidRun Ltd., its subsidiaries or employees for any direct or indirect loss or damage caused by omissions from or inaccuracies in this document. SolidRun Ltd. reserves the right to change details in this publication without prior notice. Product and company names herein may be the trademarks of their respective owners.
Introduction
Short Description | Errata | Affected PCB rev | Fix or workaround |
SD1 lane #0 not functional | Due to design bug serdes SD1 lane #0 LX2162 receive are shorted and due to that not functional. The ssignal names are SD1_RX0_N and SD1_RX0_P on the board to board header. | 1.0 | Fixed and verified in PCB rev 1.1 Will be fixed in rev 1.1 |
Fan controller PWM not functional. Tachometer and temperature sensors are functional. | Due to design bug, the AMC6821 temperature sensor and fan controller has it’s THERM# signal pulled down permanently, which forces the fan controller to set the RPM to the maximum (PWM signal becomes fixed). Notice that the Tachometer is still functional and unrelated to the THERM# signal. | 1.0 | Fixed and verified in PCB rev 1.1 Will be fixed in rev 1.1 |