Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Bluetooth LED does not work.

RJ45 LEDs

Swapped RJ45 LEDs in ports 3,4.

Info

Applies to Bedrock V3000 units earlier than 16-Oct-2023

...

with SN smaller than B3D-231016-001

...

...

PMIC programming

Random crashes due to incorrect PMIC programming.

Info

Applies to some Bedrock V3000 units earlier than 5-Sep-2023 with SN smaller than B3D-230905-001

To verify PMIC programming please follow the instructions below:

  1. download the RyzenAdj utility to

...

  1. Bedrock:

    Ui button
    colororange
    titleDownload RyzenAdj utility
    urlhttps://solidrn-my.sharepoint.com/:u:/g/personal/lior_jigalo_solid-run_com/EZ7s9GJ6wFJHhOc-M6SLWMoBavwX9VfqdZFkUo6aOIdfqw?e=WTjgFQ

  2. run: ./ryzenadj -i | grep "TDC VALUE VDD"

I if the Expected value you see is greater than 2.8 on idle then your voltage PMIC is flashed with the correct valueswhen Bedrock is in idle.