Bedrock 3D model

How to use Bedrock 3D model

The 3D model is for integration. It is accurate externally , with no internal features.

Installation notes

See also:

Orientation

Bedrock 30W and Bedrock 60W should be installed in vertical position with at least 2 cm clearance below and above for airflow.

Other mounting orientation can be considered with active cooling.

Bedrock Tile should have at least one of the walls thermally coupled to a cold plate.

Mounting notes

Rear panel: 2x M3 threadings. Depth 3mm

Rear panel can be used with

  • Bedrock wall mounting bracket

  • Bedrock DIN rail bracket

  • Custom mounting fixture

Bottom panel: 2x M4 threadings, depth 6mm

Bottom panel should not be used for direct mounting, but can be used with Bedrock foot.

 

Tile: 6x M4 threadings depth 3.5 mm on each wall

The threaded holes are intended for easy attachment to a cold plate for conduction cooling. Either of the walls can be attached at any orientation.

It is also possible to attach using another fixture e.g. a custom omega bracket.

It is advised to apply thermal interface material between wall and cold plate on the entire wall area.

 