Foreword

This article describe the procedure to flash the Wirepas stack on one or both of the of the Nordic chip available for that purpose on the gateway. This procedure is provided only for Wirepas licensees (having a full development license) that are flashing the sinks part of their license. For user not having a Wirepas development license they shall buy the gateways with the Wirepas stack installed by SolidRun.

...

Here is the table of the pin assignment to be used in the firmware

Model/Chip

Direction

Pin

Indoor/Nina B1

TX

6

Indoor/Nina B1

RX

5

Outdoor or Industrial /Nina B3

TX

45

Outdoor or Industrial /Nina B3

RX

29

Baud rate used for connection is : 125000. This is to match with the Sink Service

...